Heat Tracing in Dust Hazard Zones

INTAYE Technical Library · Jiangsu Intaye Electric Co., Ltd. · 2026-10-07

Dust hazard zones are often treated as a footnote to gas-area classification — "it's ATEX, same as before". They are not the same. Dust zones bring different temperature rules, different enclosure requirements and a surface-temperature limit that directly constrains which cable you can use.

Zone 20 / 21 / 22 in one line each

ZoneWhere it appliesPractical meaning for tracing
Zone 20Inside equipment where dust clouds form continuouslyRarely traced; if so, require the highest category equipment
Zone 21Areas where dust clouds form occasionally in normal operationCommon around conveyors, hoppers, bagging points
Zone 22Areas where dust clouds form only in fault conditionsWider envelope around the plant; many traced lines sit here

What actually changes

1. Surface temperature is the governing limit

For dust, the risk is a hot surface igniting a dust layer or cloud. The relevant value is the maximum surface temperature of the cable, junction box and any exposed metal — not the process temperature. A cable whose sheath runs at 120 °C may be unacceptable even if the line is only meant to reach 60 °C.

2. Dust layer versus dust cloud

A 5 mm dust layer insulates the surface and raises its temperature. Design limits for dust layers are stricter than for clouds. If the site has accumulating dust, the equipment must be rated for the layer thickness actually expected.

3. Equipment categories differ from gas

Dust equipment categories (1D / 2D / 3D by zone) are not interchangeable with gas categories (1G / 2G / 3G). A cable certified for gas zone 1 does not automatically satisfy a dust zone 21 requirement.

4. Enclosures and ingress

Dust needs IP6X. Junction boxes with poor sealing fill with dust, and dust inside a box changes both the temperature and the ignition risk.

5. Static and dust layers on the cable

Dust settling on the tracing cable itself is common on conveyors and silos. Consider routing that does not create horizontal ledges, and fixings that allow cleaning.

Design checklist

ItemConfirm
Dust zone20 / 21 / 22 per area, per piece of equipment
Dust typeConductivity, minimum ignition temperature, layer behaviour
Surface limitsMax surface temp for cloud and for stated layer thickness
Equipment categoryDust category (1D/2D/3D), not the gas one
EnclosureIP6X, verified sealing, cleaning access
RoutingNo ledges that accumulate dust
DocumentationZone drawing + cable/box certificates with dust marking

Common mistakes

Dust hazard project?

Send the zone drawing and dust data. We check surface temperature limits and dust-category certification before quoting.

Request a Quote
📞 in 📞

What buyers actually ask before ordering

Objections and questions repeat across markets. The five below come up in most first conversations, and answering them early shortens the cycle:

QuestionWhat the buyer really wants to know
"What is the price per metre?"Whether the total system cost fits the budget — cable is often a minor part of panel, accessories and installation.
"Can you deliver in two weeks?"Whether the project schedule is at risk; standard cable may be fast, but panels and certification take longer.
"Is it certified for our zone?"Whether the certificate covers their gas group and temperature class, not just "Ex".
"Can we use our existing panel?"Compatibility of voltage, breaker sizing, control philosophy and alarm wiring.
"Who supports it after handover?"Spare parts availability, warranty terms and local service.

Where the specification usually goes wrong

These are not commercial details — each one changes cable selection, panel design or certification scope, and therefore the price. A specification that answers them is faster to quote and cheaper to build.

快速询价 / Quick Quote